Home Company Info Product List Contact Details
Homeproduct Directory

Constant temperature humidity control instrument

Constant temperature humidity control instrument
company DongMai technology equipment Ltd.
Categories Plastic Rolling Machinery
Update2011-03-18
Original RegionChina
Constant temperature humidity control instrument

For the concrete and cement specimens conservation standards in the road transport, railways, bridges, civil construction, irrigation, hydropower, scientific research units have extensive uses and the promotion of greater value. National Standard (GBJ81-85) provides concrete specimens of curing temperature of 203C, relative humidity of 90%. In 1999, the state recommended the new standard (GB/T17671-1999)cement specimens with conservation model for the conservation room temperature of 201C, relative humidity of not less than 90%. Conservation pool water temperature of 20C1. I plant design HWS-SW-constant temperature and humidity control instrument with the following features1. refrigeration and heating equipment room on the conservation of the external avoid moist air corrosion of the equipment. extension of the useful life of equipment and reduce the failure rate, increase the reliability of the equipment can be. 2, humidifiersultrasonic humidifier with fine spray uniformity, no noise, reliability, water-conserving electricity. 3, a high degree of automation in different temperatures in different seasons, no artificial regulation, machines automatically converted to thermal cooling system. ensure a constant temperature of 201C, humidity above 90% RH. 4, computer control; The machines contain microcomputer microcomputer temperature controller and humidity controller In addition to accurate control of temperature and humidity to go, but also show the number of conservation indoor temperature and humidity, avoid the use of wet and dry ball humidity temperature look-up table for trouble. The whole apparatus consists of a set of closed refrigeration compressors, ventilation, air duct and return air components, put cooling or heating up through the air duct and drafts sent through the conservation indoor drafts back to the crew back, repeatedly makes conservation standards achieved room temperature, ultrasonic humidifier, spare tank components humidification system, computer control of its principles, as follows1, temperature controlconservation during the summer months, when the indoor temperature rose to 21C, Outdoor machines, producing a fan of wind (air conditioning refrigeration principle) when the temperature dropped to 20machines stopped working, In winter, when conservation of the indoor temperature of 19C, outdoor machines, Fans warming hot air (heat pump air-conditioning system of the thermal principle) when the temperature rose to 20C, the machine stopped working. 2, humidity controlindoor conservation requirements in more than 90% RH. Therefore, the conservation indoor set up a Taiwan ultrasonic spray humidifier, computer humidity controller effective control of the humidity of over 90%.

Constant temperature humidity control instrument on sale

Products Showcase

See more products from this supplier.

Do you want to show products of your own company? Join FREE now!

You may also be interested in: